Double Filtration of Clarifier Mud
Mayo, A.R., Rodriguez, B.M., et.al. 1984. This paper summarizes the full scale commercial application of a previously tested laboratory concept of double mud filtration to increase sugar recovery at United States Sugar Corporation’s Clewiston Mill. Belt presses for the second filtration following existing vacuum filters were used and…
Mayo, A.R., Rodriguez, B.M., et.al. 1984. This paper summarizes the full scale commercial application of a previously tested laboratory concept of double mud filtration to increase sugar recovery at United States Sugar Corporation’s Clewiston Mill. Belt presses for the second filtration following existing vacuum filters were used and…
Dextran Control in the Sugar House
Dr. Day, D.F. 1984. There is no easy solution to minimizing dextran levels in sugar but a few obvious practices should help: always mill the freshest cane possible; pay strict attention to mill sanitation especially in the problem areas; and where possible blend high and low dextran sugars to achieve acceptable penalty levels. Dextran…
Dr. Day, D.F. 1984. There is no easy solution to minimizing dextran levels in sugar but a few obvious practices should help: always mill the freshest cane possible; pay strict attention to mill sanitation especially in the problem areas; and where possible blend high and low dextran sugars to achieve acceptable penalty levels. Dextran…
Computerization of the Laboratory at the Illovo Mill
Taylor, K. 1984. The hardware and software used in the computerization of the Illovo mill laboratory are described. The implications for laboratory management and possible future developments are also discussed. Computerization of the Laboratory at the Illovo Mill. Sugar Journal, November 1984:17-22.
Taylor, K. 1984. The hardware and software used in the computerization of the Illovo mill laboratory are described. The implications for laboratory management and possible future developments are also discussed. Computerization of the Laboratory at the Illovo Mill. Sugar Journal, November 1984:17-22.
The Maxipol System
Appel, G. 1985. The heart of the Maxipol System was an intermediate carrier with a permeable apron and a tray used to collect the juice that was made to flow through this apron. The juice that flowed through the carrier having been displaced from within the blanket by the added juices was advanced to the carrier ahead as in the conventional milling system…
Appel, G. 1985. The heart of the Maxipol System was an intermediate carrier with a permeable apron and a tray used to collect the juice that was made to flow through this apron. The juice that flowed through the carrier having been displaced from within the blanket by the added juices was advanced to the carrier ahead as in the conventional milling system…
The Application of High Pressure Liquid for Process Control
Tannock, J. 1985. During the 1983 season, high pressure liquid chromatography (HPLC) has been used with great effect by Triangle Limited in their ethanol plant and sugar factory. The advantages and disadvantages of the technique, compared with gas liquid chromatography (GLC) and classical methods of analysis and…
Tannock, J. 1985. During the 1983 season, high pressure liquid chromatography (HPLC) has been used with great effect by Triangle Limited in their ethanol plant and sugar factory. The advantages and disadvantages of the technique, compared with gas liquid chromatography (GLC) and classical methods of analysis and…